Hurricane Electric

How To Configure the Ascend P130

I know it works, I've done this a thousand times before ...


Configuring For Frame Relay

Listed by menu item

(Assumes Factory Defaults)

Press CTL-D
Press P
Select "Full Access"
Enter the password "Ascend"

Configure...
	Switch Type=AT&T/P-T-P
	Chan Usage=Leased/Unused
	My Address=Customer Router Address in CIDR Notation
		This usually will be an odd number.
	Remote Address=HE Router Address in CIDR Notation
	Route=IP
	Bridge=No
30-000 30-100 Mod Config
	Nailed T1 Group=3
	Number of DS0 channels=2 (2 for 128K Service)
20-000 20-100 20-101
	Encaps=FR
	Encaps options...
		FR Prof=frame1
		DLCI=16
20-000 20-500 20-501
	Name=frame1
	Active=Yes
	Nailed Grp=3
	Link Mgmt=T1.617D
20-000 20-A00 Mod Config
	Bridging=No
	IPX Routing=No
	Ether options...
		RIP=Off
		Proxy Mode=Off
00-000 00-300 00-301 Default
	Edit Security=No
	Edit System=No
	Field Service=No 
00-000 00-300 00-303 Full Access
	Passwd=put something here and be sure to write it down

Back To Hurricane Electric's Home Page.